A DIN-rail protection relay for a single-phase 220 V supply. It watches the mains and cuts the load off when the voltage goes too high or too low, or when the current goes over the limit you set, then reconnects on its own once things are back to normal. Two red displays show live voltage and current.

  • Single-phase, 220 V AC, rated 63 A
  • Adjustable over-voltage, under-voltage and over-current trip points
  • Automatic reconnection after an adjustable delay
  • Dual LED display: live voltage and live current
  • Indicators for >V, <V, >A and Power; SET, ▲ and ▼ buttons
  • Clips onto a standard 35 mm DIN rail — 2 modules wide
Price
450.00 LE 450.00 LE

Product Overview

In an area where the mains sags, surges or comes back hard after a cut, the damage usually lands on the same things: the fridge compressor, the air-conditioner, the water pump, the TV and the router. This relay sits in the distribution board between the main breaker and the circuit you want to protect, measures the incoming supply continuously, and opens the circuit the moment the voltage leaves the window you have set or the current goes above your limit.

Everything is adjustable from the three buttons on the front. You set the over-voltage cut-off, the under-voltage cut-off, the current limit and the delay before the unit reconnects, and the two red displays then show live voltage on top and live current underneath, so the board tells you what the supply is actually doing. Four indicators on the left show which condition tripped: over-voltage, under-voltage, over-current, or simply that power is present. Recovery is automatic — once the supply is back inside the window, the relay waits out the delay and closes again by itself.

Before ordering: this is a single-phase 220 V device for a 35 mm DIN rail inside a distribution board — it is not a plug-in adapter and it should be fitted by an electrician. 63 A is the rating of the relay’s contacts, so the breaker ahead of it must be 63 A or less. It protects against voltage and current faults; it is not an RCD / earth-leakage device and not a surge arrester for lightning, so it does not replace either of those. The unit in stock is marked VA-Protector-63A on the front.

Technical Specifications

TypeAdjustable voltage & current protection relay
PhasesSingle phase (L + N)
Rated voltage220 V AC, 50 / 60 Hz
Rated current63 A
Over-voltage cut-offAdjustable, approx. 230–300 V
Under-voltage cut-offAdjustable, approx. 145–210 V
Over-current cut-offAdjustable, up to 63 A
Reconnect delayAdjustable, approx. 1–300 s
DisplayTwo red LED displays — voltage and current
Indicators>V, <V, >A, Power
Measurement error≤ 2%
Mounting35 mm DIN rail, 2 modules
DimensionsApprox. 81 × 36 × 60 mm
WiringInput on top, output on the bottom